Female-Trained Mammography Artificial Intelligence Shows Limited Diagnostic

Bioengineer.org

Source published: Site published:

Original article · فارسی

An artificial intelligence (AI) system trained only on mammograms from women was very good at finding breast gland tissue in men, but it often said gland tissue was present when it was not. It also did not agree very closely with expert radiologists, who are doctors trained to read medical images. In a detailed study at one medical center, the AI correctly found gland tissue 96% of the time when it was present. This is called sensitivity, and its score was 0.96. But it correctly recognized breasts without gland tissue only 13% of the time. This is called specificity, and its score was just 0.13. The AI often reported gland tissue in images where doctors saw only fat, which appears darker on mammograms. When researchers tested how well the AI identified potentially worrying findings using the Breast Imaging Reporting and Data System (BI-RADS), its sensitivity and specificity were moderate. Its agreement with doctors also depended greatly on the type of gynecomastia, a harmless growth of gland tissue in male breasts. The AI had the most trouble with nodular gynecomastia, which can look like cancer even though it is not. These results show how an AI trained on female breasts can struggle when used on male breasts because the two have important differences.

Breast cancer in men is very rare. It makes up less than 1% of all diagnosed breast cancers and less than 1% of all cancers in men. Even though it is uncommon, male breast cancer is an important health concern. Men are usually diagnosed five to ten years later in life than women with breast cancer, and their cancer is often at a much more advanced stage when it is found. One major reason is that men do not have routine mammogram screening programs like women do. Another reason is that both the public and healthcare professionals may know less about breast diseases in men.

The most common reason men need breast imaging is gynecomastia, which is also the most common cause of enlarged male breasts. Gynecomastia is not cancer. It happens when the ducts and supporting tissue in the breast grow because the balance between estrogen and androgen hormones changes. This can happen naturally as hormone levels change with age. It can also be caused by certain illnesses or medicines. On mammograms, gynecomastia can appear in three main patterns: nodular, which forms a rounded area of tissue; dendritic, which has a branching shape; and diffuse glandular, which involves more widespread gland tissue. Another condition, called pseudogynecomastia, happens when the breast becomes larger because of extra fat rather than growing gland tissue. The amount and thickness of tissue can be very different in these patterns, and the two breasts may not look alike. These differences affect how easily doctors can see possible problems and how confident they are in their findings. A small, rounded area of gland tissue can look like a cancerous lump, while a large amount of gland tissue can hide a smaller abnormal area.

Commercial AI systems have performed very well in mammogram screening programs for women. Some have matched or even done better than specialist breast radiologists at finding cancerous lumps and small groups of calcium deposits called microcalcifications. However, these systems are less accurate in women with dense breasts because thick breast tissue can hide important details. Male breasts have different tissue structures from female breasts, and mammograms are much less common in men. For these reasons, earlier studies used to develop mammography AI have usually left men out completely. The new study looked at how well a commercial AI system called b-box plus (version 2.1.23, made by b-rayZ in Schlieren, Switzerland) worked on male mammograms. Researchers tested its b-density tool, which identifies breast gland tissue, and its b-diagnostics tool, which finds and classifies possible abnormalities. The study included adult men who had not previously had breast surgery or received hormone treatments for gender affirmation.

This study looked back at medical images collected at one center and received official ethics approval from the Kantonale Ethikkommission Zürich on July 6, 2021 (Approval Code: 2021-01095). It followed the Declaration of Helsinki and Swiss federal rules for medical research. Researchers first found 581 adult male patients who had given general permission for their medical information to be used in research. These patients had diagnostic mammograms at University Hospital Zurich or related regional outpatient centers between 2000 and 2025. Following the study rules, researchers excluded 14 transgender men who had transitioned from female to male, representing 19 examinations. They also excluded seven men who had previously had breast surgery, representing 12 images. The final study included 560 male patients, 600 separate mammogram examinations, and 1,264 original digital images. The median age of patients at the time of imaging was 48.7 years. The middle half of patient ages ranged from 34.2 to 61.2 years. The mammograms were taken using full-field digital machines made by General Electric Healthcare, Giotto IMS, Hologic, and Siemens Healthcare. Most images were taken from an angled side view called a mediolateral oblique projection, with 1,129 images of this type. Another 135 images were taken from a top-to-bottom view called a craniocaudal projection when needed.

To create a trusted set of results for comparing the AI, two certified radiologists with 25 and 6 years of specialized mammogram experience independently examined all the digital images. They followed the fifth edition of the American College of Radiology BI-RADS guidelines, which help doctors describe and classify breast imaging findings. The radiologists could see the reasons patients had been sent for imaging and any related tissue-testing notes from referring doctors. However, they could not see the original mammogram reports or the AI results. When the two radiologists disagreed about a BI-RADS category, a third breast imaging expert with eight years of experience made the final decision. Another specialist reviewed all images to identify nodular, dendritic, or diffuse gynecomastia. Cases with only extra fat were classified as pseudogynecomastia. Images given BI-RADS category 0 or 6 were left out of the calculations comparing diagnostic thresholds and agreement scores. This left 1,239 images from 553 different patients for the main comparisons.

The researchers found gynecomastia in 70.1% of all images, or 886 out of 1,264. Dendritic gynecomastia was the most common type, appearing in 37.7% of images (476 images). Nodular gynecomastia appeared in 23.3% (295 images), and diffuse gynecomastia appeared in 9.1% (115 images). The remaining 29.9% (378 images) showed no growth of gland tissue. The BI-RADS categories assigned by human radiologists were very different between images with and without gynecomastia. This difference was statistically significant (p < 0.001), meaning it was very unlikely to be due to chance alone. Among images without gynecomastia, 64.8% were classified as BI-RADS 1, meaning no abnormal findings. Images with gynecomastia were usually classified as BI-RADS 2, meaning harmless findings. This included 97.9% of dendritic cases and 99.1% of diffuse cases. The more suspicious BI-RADS 4 and 5 categories were uncommon overall but appeared more often in nodular gynecomastia cases. Larger calcium deposits, called macrocalcifications, appeared in 34.2% of images, with no important differences between groups. Small, suspicious groups of calcium deposits appeared in only 0.5% of images (six images). Calcium deposits in breast arteries were found in 0.8% (ten images).

When researchers tested how well the AI identified breast gland tissue, it achieved a sensitivity of 0.96, meaning it found tissue that was present about 96% of the time. The 95% confidence interval was 0.94 to 0.98, showing the range of values supported by the statistical analysis. The researchers calculated this range using 5,000 rounds of a statistical method called cluster bootstrapping, which accounts for images coming from the same patients. But the AI's specificity was only 0.13, with a 95% confidence interval of 0.09 to 0.18. This means it was very poor at correctly identifying images without gland tissue. Its positive predictive value was 0.60 (95% confidence interval, 0.56 to 0.64), meaning that when it said gland tissue was present, it was correct about 60% of the time. Its negative predictive value was 0.71 (95% confidence interval, 0.58 to 0.82), meaning that when it said gland tissue was absent, it was correct about 71% of the time.

The researchers also tested how well the AI identified suspicious findings in the 1,239 mammograms that could be evaluated, using the expert radiologists' agreed results as the comparison. The AI showed moderate sensitivity and specificity, but its scores changed depending on which BI-RADS category was used as the cutoff for concern. When BI-RADS 3 or higher counted as a positive finding, the AI's sensitivity was 0.47 (95% confidence interval, 0.23 to 0.73), and its specificity was 0.83 (95% confidence interval, 0.81 to 0.85). Its positive predictive value was just 0.04, while its negative predictive value was 0.99. When researchers used the more suspicious cutoff of BI-RADS 4 or higher, sensitivity increased to 0.56 (95% confidence interval, 0.29 to 0.82), and specificity increased to 0.88 (95% confidence interval, 0.86 to 0.90). The positive predictive value was 0.06, and the negative predictive value was 0.99. These very low positive predictive values happened largely because highly suspicious breast findings were extremely rare among the men in the study.

The AI's performance changed a great deal depending on the type of gynecomastia. Nodular gynecomastia was consistently the hardest type for the system to handle. At the BI-RADS 3 cutoff, the AI's sensitivity was only 0.38 for nodular gynecomastia, and its specificity was 0.64. By comparison, specificity was 0.83 for dendritic gynecomastia and 0.95 for male breasts with no gland tissue. At the BI-RADS 4 cutoff, specificity was still only 0.74 for nodular gynecomastia, compared with 0.88 for dendritic cases and 0.97 for examinations with no abnormal findings. The AI repeatedly gave harmless nodular tissue higher, more worrying BI-RADS categories than it should have. This happened because nodular gland tissue is often thick and concentrated in a small area behind the nipple. Its shape, edges, and appearance on mammograms can look similar to a cancerous lump with clear borders. Because the AI had not been trained to recognize these harmless male breast changes, it often wrongly flagged them as suspicious. These incorrect warnings are called false positives.

Overall, the AI and human radiologists agreed poorly when assigning BI-RADS categories 1 through 5. Researchers measured this using a statistic called quadratically weighted Cohen's kappa, which shows how closely two sets of ratings agree while taking the size of disagreements into account. The overall kappa score was just 0.17 (95% confidence interval, 0.12 to 0.23), based on 1,239 images from 553 patients. The AI and doctors chose exactly the same category in only 28.0% of cases. They chose categories that were no more than one level apart in 87.1% of cases. However, agreement changed greatly depending on the breast tissue pattern. Agreement was best in male breasts without gynecomastia, where the weighted kappa was 0.37. In these cases, exact agreement was 70.8%, and agreement within one category was 95.6%. In breasts with gynecomastia, agreement was close to what might happen by chance. Nodular gynecomastia had a weighted kappa of 0.02 and exact agreement of 7.3%. Dendritic gynecomastia had a kappa of 0.03 and exact agreement of 10.9%. Diffuse gynecomastia had a kappa of 0.09 and exact agreement of 13.9%.

The researchers said their findings provide the first formal set of performance results for commercial mammography AI used on male breast images. They also pointed out important issues that doctors and researchers need to consider. The AI often gave images more suspicious BI-RADS categories because it reacted strongly to differences between the two breasts and changes in tissue thickness. These features are common in male breasts, but an AI trained only on female screening mammograms may mistake them for signs of disease. If hospitals used these female-trained systems on men without adjusting them for male breast tissue, they could produce many false alarms, especially in men with nodular gynecomastia. This might lead to unnecessary follow-up examinations, extra ultrasound scans, and invasive core needle biopsies, in which doctors remove small tissue samples using a needle. However, large studies that followed women undergoing breast cancer screening have shown that properly adjusted AI can be helpful. In those studies, AI increased cancer detection from 5.1 to 6.1 cases per 1,000 examinations while reducing radiologists' image-reading workload by 44%. This shows that AI can be useful in medical imaging when it is properly designed and adjusted for the people being examined.

The researchers also described several limits of their study. Because it looked back at records from only one medical center, the findings may not apply equally well to hospitals in other countries that use different imaging methods or treat different patient populations. The researchers also had limited information about what happened to patients after their examinations. Follow-up treatment information and detailed laboratory testing of tissue were available for only eight people who had biopsies and five tissue samples examined under a microscope. This meant the researchers could not say for certain how many men in the study actually had cancer. Because there were very few truly suspicious, high-risk findings, it was difficult to calculate reliable sensitivity scores for smaller groups of patients. The AI also did not have access to ultrasound results or additional mammogram views that human radiologists often use when making decisions. The researchers concluded that future studies should test these systems at several medical centers and follow patients forward over time. They also recommended improving AI using carefully selected male mammogram datasets that include different types of gynecomastia and cancer cases confirmed by tissue testing. These steps are needed to help AI handle the differences between male and female breast images before it can be considered for routine clinical use in men.

Subject of Research: How well AI trained on female mammograms works on male breast images with different types of gynecomastia.

Article Title: Performance of a female-trained mammography AI system in male mammography across gynecomastia patterns

Article References: Saenger, J. A., Nikolova, E., Weber, A., Dudle, A., Hildebrandt, T., Happe, J., Frauenfelder, T., & Boss, A. (2026). Performance of a female-trained mammography AI system in male mammography across gynecomastia patterns. Frontiers in Radiology, 6, Article 1949082. [https://doi.org/10.3389/fradi.2026.1949082](https://doi.org/10.3389/fradi.2026.1949082)

Image Credits: AI Generated

DOI: 10.3389/fradi.2026.1949082

Keywords: artificial intelligence, male mammography, gynecomastia, breast imaging, BI-RADS classification, nodular gynecomastia, dendritic gynecomastia, diffuse gynecomastia, radiology, breast density, diagnostic accuracy, Cohen's kappa, domain shift, macrocalcifications, computer-aided detection, breast cancer imaging