Machine Learning Model Predicts In-Hospital Mortality for Acute COPD

Bioengineer.org

Source published: Site published:

Original article · فارسی

Artificial intelligence (AI) tools that combine medical images with written medical information could greatly improve how doctors find and understand diseases. However, using these tools in hospitals is still difficult because they sometimes produce incorrect information or describe problems that are not actually visible in the images. In a new study published in Informatics in Medicine Unlocked, researchers introduced and tested a system called TrustFusion-VLM. It checks whether medical AI models make statements that are truly supported by the details in medical images. Unlike tools that create written reports, TrustFusion-VLM works after another AI system has produced a report. It checks each medical statement through several steps, including finding important image areas, checking the evidence, comparing findings, and calculating how much each statement can be trusted. The researchers tested the system without additional training using chest X-rays from the public Indiana University chest X-ray collection. They found that checking small, specific areas of an image helped separate supported findings from unsupported statements. However, they also found important trade-offs between how natural the reports sounded, how different types of evidence were combined, and how well the system reduced medical errors.

Today's medical AI models often use transformer technology and large systems trained on both images and text. They turn medical images into written descriptions, answers to visual questions, or maps showing where diseases may appear. However, these systems are often trained to produce fluent language and match the wording of existing reports. Measures such as BLEU, ROUGE, and CIDEr check how closely the generated text matches reference reports. They do not directly measure whether a diagnosis is medically correct. This means an AI system can produce a polished, well-written report that still invents medical problems, gives conflicting information, or misses diseases that are clearly visible. Because doctors may use these reports to make treatment decisions, unnoticed mistakes can spread through hospital systems and put patients at risk. Earlier studies have often looked at explaining AI decisions, connecting statements to image evidence, or reducing false information as separate problems. What has been missing is one system that checks the evidence behind each medical finding and gives it a reliability score before the report is released.

To solve this problem, the researchers designed TrustFusion-VLM with three connected parts: the Evidence Intelligence Layer, the Clinical Reasoning Layer, and the Trust and Validation Layer. The process starts with the Evidence Intelligence Layer. It receives a medical image and possible findings from an earlier AI report generator. Inside this layer, the Evidence Localization Module finds the image areas that matter for diagnosis. For example, it looks closely at body structures that may show lung infections or other abnormal material, fluid around the lungs, or an enlarged heart. It gives less attention to areas that are not useful for the diagnosis. The possible medical findings then go to the Finding Verification Network. This network checks each written statement against the image areas that were identified. Instead of comparing the statement with the entire image and producing one overall similarity score, it looks at the image patches with the strongest matches. It then gives each statement a standard verification score. This helps stop statements without clear image evidence from passing unnoticed to the next stage.

The next main part is the Clinical Reasoning Layer. It includes the Clinical Evidence Reconciliation Module, the Clinical Evidence Reconciliation Algorithm, and the Trust-Aware Clinical Reasoning Layer. Medical images can contain unclear or conflicting signs. For example, a report might say that fluid is present around the lungs in one place but say that it is absent somewhere else. Instead of simply ignoring these differences, the reconciliation algorithm calculates a reliability weight for each finding based on how strongly the image supports it. It then combines these weights into one overall reliability score for the report using a weighted average. The next reasoning stage combines three things: the verification score for each finding, the overall reliability of the report, and a confidence score for the full image. It uses set weights to calculate a final trust score for each finding. This means that findings supported by strong evidence in specific image areas have a greater effect on the final score. This is similar to how doctors consider different observations and give more importance to findings that are clearly visible.

The final part is the Trust and Validation Layer. It contains the Hallucination Detection Engine and the Clinical Faithfulness Evaluation Engine. These two tools work together to check whether the report is supported by the image. The hallucination engine compares each statement with set limits for verification confidence and trust. Statements that score below these limits are marked as unsupported or made up. Statements that pass the checks are kept in the final verified report, while rejected statements are removed. At the same time, the faithfulness engine calculates an overall score using local image verification, the combined reliability of the findings, and their trust scores. The researchers also showed mathematically that all these scores stay between zero and one without needing an extra adjustment to force them into that range. Their equations give more importance to well-supported findings than a simple average would. They also ensure that stronger evidence from image patches cannot lower the final trust score of a finding.

To test the system without mixing in changes from training an AI report generator, the researchers used TrustFusion-VLM in a zero-shot setup. This means the system was tested without additional task-specific training. It worked after a fixed report generator that used nearest-neighbour retrieval, a method that finds similar examples from stored data. The researchers used the public IU-Xray dataset, which contains 6,469 front and side chest X-ray images from 3,337 patient studies. They removed records that did not contain usable findings and removed identifying information from the images. De-identification markers were present in 42.3 percent of cases. The researchers divided the data by patient study. The stored retrieval collection contained 5,172 images from 2,669 studies, while the separate test collection contained 1,297 images from 668 studies. This ensured that images from the same patient could not appear in both groups. The main image and text model was a ready-made, general-purpose CLIP model. It used a ViT-B/32 image encoder that divided each image into 49 patches. The researchers also tested a medical-focused model called BiomedCLIP, which uses a ViT-B/16 design and divides each image into 196 patches.

The researchers created two experiments to find out how well the system could detect unsupported medical findings. The first was a controlled test in which they deliberately added false findings. They mixed real findings written by radiologists with two conflicting findings taken from other patients' records. These added findings described diseases that were not listed in the official codes for the patient being tested. This created 8,576 statements, including 2,594 deliberately added false findings. The second experiment tested statements retrieved from other reports. The researchers checked 5,697 possible findings against expert-coded MeSH and Problems labels. They used a rule-based tool similar to CheXpert, which considered negative statements and medical uncertainty across 21 chest-related medical concepts. The results showed that 31.2 percent of the 3,871 findings that could be confidently classified as present or absent were not supported by the clinical labels. The researchers measured performance using several methods: the area under the receiver operating characteristic curve, the area under the precision-recall curve, expected calibration error, and report-level clinical precision, recall, and F1 scores. These measurements were compared with reference results based on radiologists' original findings.

The test results showed that checking small areas of an image could help identify unsupported statements. However, combining several trust signals did not perform better than simpler checking methods. With the CLIP model, checking image patches achieved an area under the receiver operating characteristic curve of 0.649 in the experiment with deliberately added false findings and 0.637 in the retrieval experiment. This was much better than comparing the whole image with the text using cosine similarity. That method scored just 0.483 and performed no better than random guessing in the controlled test. However, the combined trust score reached 0.603 for deliberately added false findings and 0.641 for retrieved findings. These results were similar to the best score from comparing statements with the most relevant image patches, but they were not statistically better. The Hallucination Detection Engine removed 9.09 percent of the possible findings because they lacked image support. This caused only small changes in text-matching scores: BLEU fell by 0.0027 and ROUGE-L fell by 0.0066. More importantly, the report's clinical precision stayed almost the same. It was 0.1539 after checking, compared with 0.1546 before checking. However, clinical recall fell from 0.0975 to 0.0836 because some correct findings were also removed by mistake.

Further tests showed that finding the right image patches was the most important part of the system's ability to tell correct findings from incorrect ones. They also showed that combining evidence worked differently depending on which image model was used. When the researchers removed patch-level checking and used only information from the whole image, detection performance fell sharply. The area under the curve dropped from 0.617 to 0.486 in the controlled test. With CLIP, removing the combined reliability score or the confidence score slightly improved detection. This happened because information from the whole image sometimes weakened the more useful clues from specific image patches. But when the researchers repeated the tests with BiomedCLIP, the results were completely different. Comparing the whole image with the text became the strongest individual method, reaching an area under the curve of 0.671 for retrieved findings. Comparing individual image patches with the text worked less well. These results show that the best way to compare images and text can change depending on the AI model. The combined trust score was still useful because it gave more stable results across different models. Across all four test conditions, its average performance stayed within 0.007 of the best individual checking method, and it avoided major drops in performance.

To make sure the results were not caused by one particular way of dividing the data, the researchers also carried out five-fold cross-validation at the patient level. This method divides the full dataset into five groups and repeats the test so that each group is used for evaluation. In each round, the researchers calculated calibration settings using only the training groups and a sample of 60 patient studies. They adjusted the patch and whole-image similarity scores using their measured averages and standard deviations. The results showed that the system performed consistently. The standard deviations for all measured results were 0.028 or lower across the five rounds. The researchers also found that all three proposed scores—verification confidence, trust, and faithfulness—had statistically significant positive relationships with labels based on expert findings. Their Spearman correlation values ranged from 0.16 to 0.24. The calibration tests showed that raw verification scores tend to underestimate image support when the scores are low. Therefore, these scores are more useful for ranking findings by how well they are supported than for treating them as exact probabilities of a diagnosis. Even so, the mathematical behavior and ranking results remained consistent across both general-purpose and medical-focused image and language models.

Despite these encouraging results, the researchers pointed out several important limitations. The tests used only the IU-Xray dataset, which comes from one medical center. Access to larger and more varied collections, such as MIMIC-CXR, requires special permission. The researchers plan to use these datasets in future studies. Also, none of the system's parts received additional training for this specific task. Training them properly would require image annotations that mark the exact locations of medical findings. Such information could come from datasets like MS-CXR or Chest ImaGenome. Another limitation is that unsupported findings were identified using automatic labels based on text fields coded by radiologists. The researchers did not ask radiologists to review the images again from scratch. Most importantly, the zero-shot system did not improve overall clinical precision at the report level. This means that TrustFusion-VLM offers a transparent way to check and score medical AI findings, but it has not yet been shown to make reports safer for real-world patient care. It is too early to say that the system is ready for use in hospitals. Larger studies involving multiple radiologists and real-world testing over time are needed before such claims can be made.

Subject of Research: Checking evidence and detecting false findings in medical AI models that work with images and text

Article Title: TrustFusion-VLM: Evidence Reconciliation and Clinical Verification for Trustworthy Medical Vision-Language Models

Article References: Jagannathan, V., Poojitha, S. A., Garugu, S., Lakshmaiah, K., Naga pavani, G., & Vikruthi, S. (2026). TrustFusion-VLM: Evidence Reconciliation and Clinical Verification for Trustworthy Medical Vision-Language Models. Informatics in Medicine Unlocked, Article 101851. https://doi.org/10.1016/j.imu.2026.101851

Image Credits: AI Generated

DOI: 10.1016/j.imu.2026.101851

Keywords: Medical AI models that work with images and text, TrustFusion-VLM, Radiology report writing, Connecting findings to image evidence, Detecting false medical findings, IU-Xray dataset, Chest X-rays, Finding Verification Network, Evidence Localization Module, Medical reasoning, BiomedCLIP, CLIP model, Medical consistency, Checking whether reports match the evidence, Zero-shot verification, Combined reliability